Beijing Zhongke Jian'an (Hebei) Medical Technology Co., Ltd.
+86-312-2118111/2151555
bjzkjahb@126.com
中文
English
Home
About Us
Company Profile
Enterprise culture
Qualification Honor
Wisdom Pension
Home-based pension programmes
Community Ageing Service Program
Government Ageing Program
Products
Electric nursing bed
Travel Aid Product Series
Bath Aid Products
Extracorporeal shock wave lithotripter
Electric nursing bed ZK-HC-01 ordinary type
Electric nursing bed ZK-HC-02
ZK-HC-01 electric deflection nursing bed
Electric shift machine ZK-DY-01
Electric folding and shifting machine ZK-DY-02
Bath Aid Product Series
Bath Bed ZK-XC-01
Bathing machine ZK-XJ-01
Extracorporeal shock wave lithotripter series
Extracorporeal shock wave lithotripter KDE-2001B
Extracorporeal shock wave lithotripter KDE-2002B
Extracorporeal shock wave lithotripter KDE-2002A
News
Company News
Exhibition Information
After-sales service
FAQ
Solution
Contact Us
Online Mall
Global Business
Stone Crushers Domestic Business
Stone crusher foreign business
Inquiry
Troubleshooting Methods of Electric Nursing Bed
Problem one: motor failure Countermeasures: Check whether the circuit connection is normal and whether there is any looseness or short circuit. If the motor is damaged, replace it with a new one. Remind the user to avoid overload use, in accordance with the provisions of the load weight operation. Problem two: remote control handle failure Countermeasures: Replace the control handle. Check whether the power supply has electricity. The energizing line is damaged. Problem three: loose bed structure Countermeasures: Tighten the screws and check the connection parts. Replace or repair worn parts. Question four: mattress deformation Countermeasures: According to the warranty, replace the mattress with a new one for the user. It is recommended that users turn over the mattress regularly to extend the service life. Question 5: excessive noise Countermeasures: Lubricate and maintain related parts. Troubleshoot and repair faulty mechanical components.
Key words:
25
2024/07
Troubleshooting Measures of Electric Shifting Machine
Fault one: power supply problem Treatment measures: Check whether the battery is aged or damaged, and replace the battery with a new one if necessary. Confirm whether the charger can work normally, if not, replace the charger. Check the power line connection to ensure that the line is stable and not loose. Fault two: the movement is not smooth Treatment measures: Check whether the wheels are worn or deformed, and replace the damaged wheels in time. Clear debris and obstacles from the track. Fault three: lifting or lowering fault Treatment measures: Check whether the electric push rod is normal, repair or replace the faulty electric push rod. Detection of control system components and lines, repair or replace faulty components. Fault four: sling damage Treatment measures: Replace the damaged sling in time to ensure safe use. Remind the user to use the displacement machine according to the specified load weight. Fault five: excessive noise Treatment measures: Lubricate and maintain the relevant mechanical parts. Tighten loose parts.
Electric bathing bed fault treatment measures
Problem one: water leakage Countermeasures: Inspect and replace aging seals. Repair or replace the broken water-repellent cloth. Re-tighten connections to ensure tight connections Problem two: electric component failure Countermeasures: Check whether the motor is running normally, and replace the motor if it is damaged. Check the circuit for open circuit, short circuit, etc. and repair it. If the control module fails, replace the control module with a new one. Question three: bed rust Countermeasures: Grind the rust and recoat it. Remind the user to keep the environment around the bath bed dry to avoid long-term water accumulation. Problem four: control panel failure Countermeasures: Replace the damaged keys. Examine and repair the control panel wiring.